The ScreenConnect extension attack: a remote-access checklist for MSPs

On November 11th, 2026, ConnectWise said it was aware of reports of unauthorized access to ScreenConnect partner accounts, and it disabled five third-party extensions as a precaution. Its initial assessment points to those add-ons, not a ScreenConnect vulnerability, and it is still validating that. Here is what to do now, and the remote-access inventory your clients will ask for.

News
Regentra Team
November 14, 2026
Regentra brief: the ScreenConnect extension attack and five checks for MSPs, from disabling the named extensions to recording the incident

On Wednesday, November 11th, 2026, ConnectWise posted a security advisory about reports of unauthorized access to ScreenConnect partner accounts and unauthorized remote-access software in customer environments. By Friday, Huntress, Microsoft Threat Intelligence, and other researchers had published their own findings.

The thread that matters most for MSPs and MSSPs, based on what ConnectWise has said so far, is not a flaw in the core ScreenConnect product. ConnectWise says it found no evidence that initial access involved a ScreenConnect vulnerability. Its initial assessment suggests the activity may involve abuse of independent third-party extensions that partners had installed, and ConnectWise says it is continuing to validate that assessment. This post covers what the primary sources say, what ConnectWise tells partners to do now, and the remote-access inventory your clients will ask you to show.

Watch the 60-Second Briefing: Watch our narrated YouTube Short on the ScreenConnect add-on attack and what MSPs should check now, on YouTube (@Regentra-PSA).

What happened, in order

  • November 11th, 2026. Huntress says it saw suspicious activity across multiple ScreenConnect environments starting at about 17:47 UTC (12:47 PM ET). It counted at least 288 managed endpoints across 48 organizations that use Huntress, all within 90 minutes. At 22:45 UTC (5:45 PM ET), ConnectWise posted its advisory. It named five independent third-party extensions that may be associated with the activity and disabled them in about 400 partner environments as a precaution.
  • November 12th, 2026. ConnectWise said it had found no evidence of a compromise of ConnectWise infrastructure, or that initial access involved a ScreenConnect vulnerability. It said its initial assessment suggests the activity may involve a threat actor's abuse of independent third-party extensions, and that it is continuing to validate this assessment. A CVE, CVE-2026-127063, was assigned to the RMM+ extension.
  • November 13th, 2026. Huntress reported a second wave from new infrastructure: 205 hosts across 41 organizations. Microsoft Threat Intelligence confirmed the activity ConnectWise reported and published its analysis of the toolkit, called SCKit. ConnectWise updated its advisory at 21:15 UTC (4:15 PM ET), telling on-premises partners to disable the named extensions immediately.

Where the evidence points: an add-on

Huntress says the activity seems to be related to one of the extensions ConnectWise disabled, RMM+. Huntress describes RMM+ as a third-party extension that lets another tool manage ScreenConnect sessions without a technician working through the console. It checks a shared access key stored in the extension's settings. That key check sits outside ScreenConnect's own user accounts, roles, and MFA. Huntress says versions 1.0.31 and 1.0.32 would accept a blank key if an administrator had never set one.

The CVE record that ConnectWise published for CVE-2026-127063 describes the same class of problem: the extension uses a static API secret by default, and environments that kept the default may accept unauthorized requests, including commands sent to managed agents. The record says no fixed RMM+ version has been announced. Disabling the extension is the current mitigation.

One line in the Huntress write-up deserves a second read. Huntress says most RMM+ installs it found were legitimate, "usually added for a project and left in place." That is the pattern to look for in your own stack. MFA on the console does not help if a side door never asks for it, and nobody remembers the side door is there.

ConnectWise named these five extensions for disabling:

  • Labtech Plus
  • RMM Plus
  • RMM+
  • RMM Plus Password Link
  • RMM+ Password Link

In its November 13th update, ConnectWise also said it had disabled ITBoost Integration, RepairShopr Integration, and Guest Session Starter in cloud environments and its marketplace as a precaution, and it encouraged partners to do the same. ConnectWise is clear that having one of these extensions installed does not, on its own, mean an environment was compromised.

What the toolkit does

Microsoft says deployment starts with commands sent through ScreenConnect that silently install a second client connected to attacker-controlled infrastructure. A batch launcher pulls a PowerShell decoder, which unpacks SCKit. The toolkit sets up persistence with scheduled tasks and registry Run entries, and it deploys a component Microsoft calls RelayTrap, which is designed to deliver a payload to a technician who connects to the infected machine.

ConnectWise says that spread technique is blocked by the fix for CVE-2026-84869, which shipped in ScreenConnect client version 26.6.5 on September 8th, 2026. ConnectWise also says researchers have not observed the spread technique succeed at this time. The catch is the word "client." Updating the server or the cloud console does not update the client on each technician's computer.

Diagram: the five-part remote-access inventory for MSPs, from every tool and extension to a dated record of who checked and what changed

What ConnectWise tells partners to do now

These steps come from the ConnectWise advisory as updated on November 13th, 2026:

  1. Disable the named extensions. On-premises partners must do this themselves, because ConnectWise cannot disable extensions on your servers. Do not re-enable or reinstall them until ConnectWise says otherwise, and confirm they stay off on every instance.
  2. Verify every technician client. Each technician computer should run ScreenConnect 26.6.5 or later. ConnectWise says the console version alone does not confirm this.
  3. Reduce file-transfer permissions while updates are pending. Review roles and turn off Transfer Files wherever it is not needed. ConnectWise calls this a temporary measure, not a substitute for updating clients.
  4. Review for unauthorized activity. Preserve and examine Run Command history, extension API activity, administrative accounts, permission changes, and Toolbox records.
  5. End active sessions from a trusted device. Revoke active ScreenConnect sessions and the related identity-provider sessions, reset relevant credentials, and enforce MFA. ConnectWise notes that password resets alone do not end existing sessions.
  6. Investigate with separate tools. Do not use ScreenConnect to investigate or clean suspected endpoints. Use EDR or another trusted out-of-band method, and include technician computers that connected to affected devices.
  7. Remove what is left. Isolate affected devices, preserve evidence, clear unauthorized queued commands and tools, and remove persistence before you restore connectivity.

If you do not run ScreenConnect, the advisory is still a useful template. Every remote-access tool you run has its own add-ons, integrations, and API keys.

The inventory your clients will ask for

Clients in healthcare, finance, and the defense supply chain read the same headlines you do. Expect a version of one question: "Were we affected, and how do you know?" A good answer is a dated record, not a reassurance. Before anyone asks, be able to show:

  • Every tool. Each remote-access tool and instance you run, cloud and on-prem, and which clients each one reaches.
  • Every add-on. Each extension, plugin, and integration on those tools, who added it, why, and whether it is still needed.
  • How each one signs in. A named user with MFA, or a shared key or API secret. If it is a key, confirm it is set, unique, and rotated.
  • Technician clients. The installed client version on every technician computer, checked on the machine itself.
  • A dated record. Who checked, when, what you found, and what you changed.

That last item is the one most teams skip. It is also the one an auditor or a client's security questionnaire will ask for later. You can read more about building that habit for every client in our guide on managing 50 clients without losing compliance visibility.

Which controls this touches

Coverage of this incident falls under the incident response controls your clients' frameworks already require, plus the remote access, third-party, and change management controls around them. The value is in logging the incident in the PSA against the client, and having an easy-to-find record of every incident when an auditor or a client asks.

  • Incident response. SOC 2 CC7.3 and CC7.4 (evaluate security events; respond with a defined incident response program). ISO/IEC 27001:2022 A.5.24, A.5.25, A.5.26, and A.5.28 (incident management planning and preparation, assessment of security events, response to incidents, collection of evidence). NIST CSF 2.0 RS.MA-01 and RS.AN-06 (execute the response plan with relevant third parties; record investigation actions and preserve their integrity). HIPAA Security Rule 45 CFR 164.308(a)(6) (security incident procedures: identify, respond, mitigate, and document security incidents and their outcomes). CMMC Level 2 IR.L2-3.6.1 and IR.L2-3.6.2 (incident handling; track, document, and report incidents).
  • Remote access and activity review. CMMC Level 2 AC.L2-3.1.12 and AC.L2-3.1.15 (monitor and control remote access sessions; authorize remote execution of privileged commands). HIPAA Security Rule 45 CFR 164.312(b) (audit controls that record and examine system activity). HIPAA Security Rule 45 CFR 164.308(a)(1)(ii)(D) (regular review of information system activity records).
  • Third-party and vendor risk. SOC 2 CC9.2 (assess and manage risks from vendors and business partners). ISO/IEC 27001:2022 A.5.19, A.5.21, and A.5.22 (supplier relationships, the ICT supply chain, and monitoring and change management of supplier services). NIST CSF 2.0 GV.SC-07 and DE.CM-06 (understand, record, and monitor supplier risk; monitor external service provider activity).
  • Change and configuration management. SOC 2 CC8.1 (authorize, document, test, and approve changes to infrastructure and software). ISO/IEC 27001:2022 A.8.9, A.8.19, and A.8.32 (configuration management, installation of software on operational systems, change management). NIST CSF 2.0 ID.AM-02 and PR.PS-01 (keep software and service inventories; apply configuration management). CMMC Level 2 CM.L2-3.4.3 (track, review, approve or disapprove, and log changes to systems).

HIPAA references are to the Security Rule as currently in force (eCFR, section last amended January 25th, 2013), not the proposed update. The ISO/IEC 27001:2022 items are Annex A control titles. Which controls apply depends on each client's scope.

Keep the record where the work happens

Regentra puts PSA and compliance in one platform, so this response does not have to live in one tool and its proof in another. The incident, the tickets, and the evidence sit in one platform, and the follow-up and proof sit on the client's controls. Here is how that looks for an incident like this one:

  • Log it against the client. Each client is its own tenant, and when you switch to a client every compliance and PSA view shows that client's data. Report the incident there with how it was detected (a vendor or third party can be the source), the affected systems and data types, and the initial actions. (docs: clients, docs: incidents)
  • One ticket for every affected client. When one event hits several customers, promote one ticket to a master and link each customer's ticket as a child. Resolving the master can be applied to every linked child. (docs: tickets)
  • Tie the follow-up to the control. Create a compliance issue, link it to the control it affects, assign an owner and a due date, and attach evidence when it is resolved. Each issue links to one control. (docs: audit lifecycle)
  • Track the fixes as tickets. Gap analysis turns unimplemented controls into remediation tickets, one per control, with guidance pre-filled. (docs: gap analysis)
  • Keep the proof. Every status change needs a reason, the timeline is append-only, the Evidence tab is a chain-of-custody log, and closing the incident logs compliance evidence tagged as an incident-response artifact. Evidence attached to a control counts toward every framework that control maps to. (docs: incidents, docs: evidence collection)
  • Track the vendor risk. Record "unreviewed remote-access add-ons" as a third-party risk with inherent and residual scores, an owner, a due date, and a review cadence. Accepting a risk needs a written justification. (docs: risk register)
  • Pull the record when asked. The incident Report tab generates one PDF with the classification, timeline, actions, root cause, corrective actions, and the evidence log. (docs: incidents)

Bolted On vs. Built In

With separate tools, the tickets live in a PSA, the controls live in a compliance tool or a spreadsheet, and the proof is scattered across both. Regentra puts compliance and PSA in one platform: the incident and the fix live alongside the client's controls, and the follow-up and proof sit on the control.

  • Incidents. Bolted on: notes in a ticket, and the proof filed somewhere else. Built in: an incident record where every status change needs a reason, the timeline is append-only, and closing it logs compliance evidence tagged as an incident-response artifact (docs).
  • Tickets. Bolted on: fixes tracked in the PSA with no link to a framework. Built in: gap analysis creates one remediation ticket per control, with the control code pre-filled, and failing monitoring findings flow into the PSA as tickets (docs, docs).
  • Configuration changes. Bolted on: a change note in one place and the config proof in a folder. Built in: the ticket for the change is linked to the affected asset, can request the customer's approval for the change window, and the configuration export is attached to the control as evidence (docs, docs, docs).
  • Controls and proof. Bolted on: a spreadsheet that maps controls by hand, with evidence copied per framework. Built in: evidence attached to the control counts toward every framework that control maps to (docs).
  • Finding the record. Bolted on: searching several tools when the auditor or client asks. Built in: switch to the client and every compliance and PSA view shows that client's data, the Evidence Map shows where evidence has been collected, and the incident report is one PDF (docs, docs, docs).

If you run security services for many clients, the MSSP overview shows how this works across tenants, and the PSA overview covers the service desk side.

Ready to try it?

14-day free trial, no credit card required.

Start your free trial

Or request a demo.

Frequently asked questions

Was ScreenConnect itself vulnerable?

ConnectWise says it found no evidence that initial access involved a ScreenConnect vulnerability, and it is still validating its assessment. CVE-2026-127063 covers the third-party RMM+ extension, and the CVE record says the ScreenConnect server and client are not affected by it. Separately, the fix for CVE-2026-84869 in client version 26.6.5 or later blocks the toolkit's attempted spread to technician computers.

We use cloud-hosted ScreenConnect. Do we need to do anything?

Yes. ConnectWise disabled the named extensions in cloud environments, but it still asks every partner to verify that each technician client runs 26.6.5 or later, review activity, and revoke active sessions from a trusted device.

If one of these extensions is installed, were we compromised?

Not necessarily. ConnectWise says having an extension installed does not, on its own, establish compromise. Disable it, then review Run Command history and extension API activity with separate tools such as EDR.

Is there a fixed version of RMM+?

Not yet. The CVE record says no fixed RMM+ version has been announced and that disabling the extension is the current mitigation.

What should we tell our clients?

Give them a short, dated summary: which remote-access tools you run, which add-ons you checked, what you found, and what you changed. Keep the record so you can show it again at audit time.

Sources